1.INSPECT LIGHT CONTROL RHEOSTAT







| *1 | Knob |
| *a | Component without harness connected
(Light Control Rheostat) |
Inspect the light control rheostat.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 9 (T) - 6 (E) | Always | 10 +/-2 kΩ |
| 7 (TR) - 6 (E) | Knob turned fully upward | 10 +/-2 kΩ |
| 7 (TR) - 6 (E) | Knob turned fully downward | Below 50 Ω |
| 7 (TR) - 6 (E) | Knob turned from fully upward to fully downward | 10 +/-2 kΩ → Below 50 Ω |
If the result is not as specified, replace the light control rheostat.






| *1 | Knob |
| *a | Component without harness connected
(Light Control Rheostat) |
Inspect the TAIL cancel switch.
The TAIL cancel switch is built into the light control rheostat.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 9 (T) - 8 (TC) | Knob turned fully upward
(TAIL cancel condition) |
10 kΩ or higher |
| 9 (T) - 8 (TC) | Knob not turned fully upward | Below 1 Ω |
If the result is not as specified, replace the light control rheostat.